Back to Resumes List

HVAC Maintenance Supervisor

Objective


Quest to work in real professional atmosphere enables to cope up with the emerging as well as the technology and scope widening the spectrum.


Experience


EXPERIENCE

Presently working as HVAC maintenance supervisor in Sultan Qaboos University

Al khoud, Muscat, Sultanate of Oman under GENET Co (Electro Mechanical maintenance Co) from December 2008.



? Work Responsibilities



• Supervising of 16 HVAC technicians and 6 assistant technicians, working in central part of University which includes Faculty and Administration area,

• Total 52 number of air cooled chillers (90 to 300TR), related equipments like AHU, FCU, VAV and other types of Air conditioning equipments like DX units, package unit, split units and window units are maintaining by our team,

• Also our team responsible for maintenance of Fume Extract fan units & different kind of refrigeration equipments like cold rooms, refrigerators freezers and drinking fountains etc,

• Carry out of PPM and break down works in different buildings of University by coordinate with CMMS (Computerized Maintenance Management System) department,

• Preventive and breakdown maintenance is carried out such that minimum breakdowns occur and minimum inconvenience is caused to the end user,

• Coordinate with purchase & store department and arrange suitable spare parts by contacting suppliers,

• Taking approval for repair and preventive maintenance certificates created by CMMS, by coordinate site inspection with Authority inspectors



? August, 2007-to October,2008 – For General Authority of health services (GAHS) Mafraq, Abu Dhabi, UAE under M/S BEN KHALEF EQUIPMENTS & MACHINARIES



Mechanical Supervisor- HVAC



Supervision of operation and maintenance team of Different kind of A/C and refrigeration equipments located in different buildings of Health Authority Mafraq, Abu Dhabi, UAE

(All Equipments are operating and controlling by Honeywell EBI R 301 BMS system)



• Air Cooled Water Chillers

? York-YDAJ 87 HU750 PA - 330 TR

? York - YCAJ 97 AU 750 PA – 179 TR / YEAJ 977 PX 750 PA – 250 TR

? SKM – APCC 5281 / APCD 5330 B / APCC 5340 YM

? CARRIER 30 GH 100164 NEE -86 TR / 30 GT -200TR

• AHU s, FCUs & VAVs

YORK, CARRIER, SKM and SAIVER

• PACKAGE UNITS

YORK, CARRIER, SKM and MITSUBISHI

• Cold rooms (Drugs, Vaccine, Vegetables and Meat



March, 2003-December,2006 – For Ministry of Health, Sultanate of Oman under Oman National Electric Company (SAOG)

HVAC Supervisor

Supervision in Operation, Maintenance and Repairing of,

? Air cooled Reciprocating water Chiller –MITSUBISHI ELECTRIC, CA 160 KB

? AHUs, Controls by Landis & Gyr

? Centralized DX Split Units – CARRIER, 38 AH (10 to 55 tons)

? Air cooled Reciprocating Water Chiller—CARRIER (Floutronic type, 30GT)

? Package units – CARRIER, 50 TJS

? Cold rooms – BITZER and FOSTER

? Refrigerating machine (Mortuary)—THALHEIMER

? Refrigerators, Deep freezers, Window A/Cs, Split A/Cs and Water coolers of all kinds



Operating and controlling of BMS (Johnson controls-METASYS & M3 WORK STATION) which is connected with HVAC system (Chiller plant, AHU, FCU, VAV, Humidifiers, Heaters, DX Units, Package Units and Extract fans), RO Plant, Sewage treatment plant, Steam boilers, Generators, Electrical Distribution System, Calorifiers, Cold rooms, Medical gas system and Fire alarm system



? 1997 – 2002 for Saudi Telecom under M/S I MAN Co, Riyadh, KSA



HVAC Team Leader



Operation, Maintenance and Repairing of,



? Air cooled Reciprocating Water Chiller—YORK and TRANE

? Micro processor controlled Package Units—TRANE and CARRIER

? Split A/C Units—CARRIER, YORK, PEARL, MITSUBISHI and DYKIN

? Refrigerators, Water coolers, Deep freezers and Window A/Cs of all kinds



? 1994—1997 for Grasim Industries Ltd, Calicut, Kerala, INDIA



PLANT SUPERVISOR (TRAINEE)



Supervision of Central A/C Plant


Education


PROFESSIONAL QUALIFICATION



1990—1994 3 Year DIPLOMA IN MECHANICAL ENGINEERING – Second class

Kerala Government Poly Technic, Calicut, Kerala, INDIA



COMPUTER SKILLS



1995—1996 DIPLOMA IN COMPUTER APPLICATION

Markaz Collage of Engineering, Calicut, Kerala, INDIA ,


Certification


PROFESSIONAL QUALIFICATION



1990—1994 3 Year DIPLOMA IN MECHANICAL ENGINEERING – Second class

Kerala Government Poly Technic, Calicut, Kerala, INDIA



COMPUTER SKILLS



1995—1996 DIPLOMA IN COMPUTER APPLICATION

Markaz Collage of Engineering, Calicut, Kerala, INDIA ,



? Participated Training courses

? CARE 4.0 Engineering tools by Honeywell (HBS AMS Abu Dhabi) , DEC-2007

? EBI R310 Building Management system by Honeywell (HBS AMS Abu Dhabi), Jan-2008


Skils


Supervising of HVAC Operation and Maintenance team

Air cooled chillers - Reciprocating/Screw

DX unit /Package unit / Split Unit

AHU/FCU/VAV/Fume cupboards

Trouble shooting and routine scheduled maintenance

documentation of everything related with O&M



Cold rooms / Freezers / Mortuary / All kinds of other refrigeration equipments


 


good knowledge in Installation of additional Fan Coil units,

Split AC

experience in commissioning and taking over of DX and Package units

Muscat,
View Contact Information